The State Council production safety inspection team reported outstanding problems and typical cases.

  BEIJING, May 3 (Xinhua) According to the official WeChat message of the Emergency Management Department, following the inspection and inspection of the provincial government’s safety production and fire control work in the State Council in 2020, in order to effectively improve the effectiveness of the inspection and inspection, the the State Council Safety Committee Office recently dispatched several secret investigation and unannounced visits to key industries such as mines, chemicals, industry and trade, water transportation, fishing vessels, gas, etc., and went to various places to cooperate with the inspection and inspection to carry out "four no, two straight" secret investigations and unannounced visits to verify the clues of problems and strengthen the exposure of typical cases. The outstanding problems and typical cases discovered in the first batch are reported as follows:

  First, Inner Mongolia Chifeng Shanchuan Mining Co., Ltd. secretly investigated the unannounced visits

  Basic situation: the mine adopts underground mining and shaft development, mainly mining lead ore and zinc ore, with an area of 0.0799 square kilometers and a production capacity of 90,000 tons/year. The secret investigation team consulted the company’s enterprise management system, safety production responsibility system, accident hidden danger management system, emergency plan and drill, safety risk early warning and emergency prevention announcement system, safety facilities design and other materials, and consulted some punishment cases of the local emergency management bureau, and finally went deep into the underground and tailings pond for on-the-spot inspection.

  The main problems: The inspection found 16 hidden dangers, among which the outstanding hidden dangers are: First, the situation of the mine going down in April, 2021 was randomly checked. Only one day, the wellhead personnel were recorded, and the time of going down was 1.5 hours, which was inconsistent with the written record of the mine leader going down with the class, and there was fraud, which violated the requirements of the Interim Provisions on the Leadership, Supervision and Inspection of Metal and Non-Metal Underground Mining Enterprises. Second, the investigation and management of hidden dangers of accidents has not been notified to employees, which violates the requirements of Article 38 of the Safety Production Law. Third, there are no road signs at the mine roadway intersections, which violates the stipulation that "all intersections of the roadway should have eye-catching road signs to indicate their location and the direction leading to the ground exit" in 5.2 of the Code for the Construction of Emergency Evacuation System in Metal and Non-metallic Underground Mines (AQ 2033-2011). Fourth, the backup motor equipped with the main ventilator at the mine return air wellhead is placed outside the fan room in the open air, which does not effectively protect the motor. If the backup motor cannot work normally, it is equivalent to that the main ventilator is not equipped with a backup motor. Fifth, the underground goaf was not treated according to the design requirements of safety facilities. Sixth, the tailings pond adopts mechanical flood discharge. Seventh, on-site assessment of the mine manager’s knowledge of relevant provisions on safety production was conducted, and only one question could be answered. Spot-check an employee’s safety training test paper, and the test score was 82, but the employee answered the same test paper at the scene, and the test score was only 46 after less than a month.The quality of safety education and training is not high and it is a mere formality.

  Suggestions on rectification measures: The unannounced investigation team pointed out that Shanchuan Mining Co., Ltd. has a mining area of only 0.0799 square kilometers, a production capacity of 90,000 tons/year, a small scale, short service life, low personnel quality and chaotic on-site management, and suggested that it should be ordered to stop production for rectification in accordance with Article 108 of the Safety Production Law. For the problems found in this unannounced visit, they will be handed over to the local emergency management department for punishment according to law, and the situation will be fed back to the State Mine Safety Supervision Bureau.

  Second, Beijing Economic and Technological Development Zone Hualian Printing Co., Ltd. secretly investigated the unannounced visits.

  Basic information: The unit is located at No.3, Donghuan North Road, Beijing Economic and Technological Development Zone, with an area of 27,500 square meters and a building area of 36,000 square meters (production workshop of 16,392 square meters). The unannounced visit team focused on the enterprise responsible person’s performance of safety production duties, accident risk management, emergency plans and drills, consulted the unit’s safety production work files, and inspected the safety key parts, fire control facilities operation, electrical fire safety and emergency response capabilities.

  The main problems are: First, the information of key posts and special types of workers in the safety production files is not detailed, the post category and practice scope of special types of workers are not clear in the registration list, and the practical ability of operators in the fire control room is not strong. Second, the focus of the unit’s fire inspection is not prominent, and the safety key parts are not clearly defined according to the production process. Third, the cable port at the bottom of the low-voltage distribution cabinet in the distribution room is not tightly blocked, which is easy to cause the fire to spread and expand. Fourth, the fire fighting and emergency evacuation plan is not detailed, not set according to the actual situation of the production enterprise, the responsibilities of each post are not clear, and the emergency response capacity of the micro fire station needs to be improved.

  Suggestions on rectification measures: The unannounced interview group pointed out that the main responsibility of enterprise safety production should be strictly implemented, the training of key types of workers should be strengthened, the operation process should be standardized, effective preventive measures should be taken for high-risk parts, targeted plans and disposal measures should be formulated, the education and training of employees should be strengthened, and the level of intrinsic safety prevention and emergency response ability should be improved. In view of the hidden dangers of the problems found, the secret investigation team has urged the local competent department to issue a notice to the enterprise to be ordered to correct, and the administrative punishment is being processed.

  3. Guangxi Guangming Wharf Storage Co., Ltd. secretly investigated the unannounced visits.

  Basic information. Founded in 1995, the company has a 10,000-ton trestle wharf with a designed annual throughput of 1.2 million tons. There are 13 refined oil storage tanks in the oil depot area, which are equipped with 2 truck loading platforms and 8 sets of loading cranes. And the special loading line for dangerous chemicals with 52 parking spaces on four tracks, with a designed transfer capacity of 2 million tons. The secret investigation team raided the safety management of the company’s shift change, the person in charge of the company’s shift on duty, emergency maintenance and repair arrangements, and spot-checked the implementation of security management in the automobile loading station and the central control room.

  The main problem. A total of 17 hidden dangers of various problems were found. The outstanding hidden dangers are as follows: First, the management of the combustible gas detection and alarm system in the enterprise is chaotic. For example, the control system in the central control room shows that many combustible gas detection and alarm devices with public parts numbered GT003, GT020 and GT023 are in a fault state; The first-level alarm and the second-level alarm of the alarm device numbered GT0303 are set too high to realize its early warning function. The alarm instrument numbered GT005 is in a high (first-class) alarm state and has been left unattended for a long time; There is no combustible gas alarm device on the second platform of automobile loading, which does not meet the requirements of Design Standard for Detection and Alarm of Combustible and Toxic Gases in Petrochemical Industry (GB/T 50493-2019), and there are significant safety risks. Second, the central control room and cabinet room of the enterprise have opened doors and windows on the side of the tank farm with fire and explosion hazards; There is a dormitory above the enterprise office building, which is only about 40 meters away from the adjacent tank farm, which does not meet the requirements of fire and explosion prevention. Third, non-explosion-proof electrical appliances were placed in the operating room of the No.7 loading post of gasoline and diesel, which violated the requirements of Code for Design of Electrical Installations in Explosive Hazardous Environments (GB50058-2014). Fourth, the safety instrument system in the central control room of the enterprise shows that all the interlocks of the "Tank Group I" storage tanks are in the state of removal, and the interlock removal procedures have not been handled. The production management personnel are not clear about the setting and commissioning of the process interlocks in the tank farm, which violates the Network Security Distributed Control System (DCS) of the Industrial Automation and Control System. Part 2: Management Requirements (GB/T33009.2-2016) requires that there are significant risks.

  Suggestions on rectification measures: The unannounced investigation team pointed out the systematic problems in safety production to enterprises, urged the Guangxi Zhuang Autonomous Region Security Committee Office to coordinate the traffic management department, and ordered Guangxi Guangming Wharf Storage Co., Ltd. to stop production and rectify. On April 26th, Qinzhou Branch of Beibu Gulf Port Administration of Guangxi Zhuang Autonomous Region has issued a notice to order rectification, ordering enterprises to complete the rectification of hidden dangers of accidents and to resume operations after examination and approval.

  Four, Liaoning Penghui Casting Co., Ltd. secretly investigated the unannounced visits.

  Basic information: The company was established in September 2012. It is a comprehensive iron and steel enterprise integrating sintering, pelletizing, ironmaking, steelmaking, steel rolling, oxygen production and power generation. The annual output of molten iron is 2.26 million tons, crude steel is 2.3 million tons, and the annual output of steel is 2 million tons. The secret investigation team inspected the self-examination and self-improvement of the company’s three-year special rectification of production safety in 2020, and conducted on-site inspections on production units such as sintering, ironmaking and steelmaking.

  The main problems are as follows: First, the nitrogen purge pipe of the gas dry dust collector box of No.2 blast furnace in ironmaking is directly connected with the dust collector box, and the blind plate is not installed to realize reliable separation from the gas in the dust collector. When the gas dust collector is working normally, if the gas source of the nitrogen purging pipeline is interrupted or the pressure is lower than that of the gas in the dust collector box, the gas may leak back into the nitrogen system due to loose sealing, and enter the waste heat power generation system protected by nitrogen (there should be no gas), and an explosion may occur. Second, the general bridge crane is used to lift the liquid slag in the steel slag workshop, and the metallurgical casting crane with fixed gantry hook is not used. The requirements of metallurgical casting crane in structural design, manufacturing and safety facilities are generally higher than those of general bridge crane, such as higher mechanical strength and a set of take-off and landing braking device, etc., and its intrinsic safety level is higher, which can prevent the slag tank from falling and overturning accidents to a greater extent. The third is the crane that lifts molten metal, and the annual flaw detection lacks items such as beam weld and trunnion pin; The routine inspection lacks the wire rope end fixing piece, the plate hook pin shaft clamping plate and so on. If the welding seam of the cross beam is broken, the wire rope fastener is fatigued, or the pin shaft clamping plate fails, it will directly lead to the fall of the crane or molten metal tank, resulting in mass casualties. Fourthly, the sinter temperature measurement on the sintering belt is not interlocked with the cooling spray device. When the sinter temperature is too high, if the spray device can’t be started in time, the sinter can’t be cooled down, which will easily lead to a belt fire accident for transporting sinter.The above problems violate the requirements of Articles 33 and 38 of the Law of People’s Republic of China (PRC) on Work Safety.

  Suggestions on rectification measures: The unannounced investigation team requires enterprises to make changes to the hidden dangers found, that is, to make changes as soon as they know them, and to make inferences about them and make comprehensive self-examination and self-correction. The emergency management department of Liaoning Province and the emergency management bureau of Liaoyang City are required to immediately issue documents such as on-site treatment measures for the problems found in this inspection according to law, and should promptly file a case for investigation, deal with it seriously according to the law, strengthen supervision and guidance, ensure that rectification is in place, and achieve a closed loop of law enforcement.

  Five, Zhoushan, Zhejiang Province, water traffic and fishing vessel safety unannounced visits.

  Basic information: The undercover investigation team inspected the Xing-zhong cargo terminal and shenjiamen fishing port in Ao Mountain, randomly boarded the ship to inspect the development of safety production of cargo ships and fishing boats, and conducted face-to-face research and exchanges with the heads of grass-roots fishing boat management service organizations, fishermen’s representatives and shipping enterprises.

  Main problems: After on-site inspection, it is found that there are 14 hidden dangers in the safety management of bulk carrier Yuechengshan of Tangshan Oriental Shipping Co., Ltd., and the outstanding ones are as follows: First, the fire dampers of some vents have serious defects such as jamming, and once the warehouse catches fire, it cannot form a closed space, which will lead to the release of carbon dioxide and affect the fire fighting operation. Second, the cable pipe of the depth sounder between the third cargo hold and the fourth cargo hold is not watertight at the opening of the deck. If it is attacked by heavy wind and waves, it will easily cause a large amount of seawater to pour into the cargo hold, resulting in cargo damage and even sinking of the ship. Third, the third officer in charge of life-saving equipment and fire-fighting equipment on board will not start using lifeboats, and will not be able to escape and save themselves at the first time in case of emergency; The second mate in charge of driving equipment, signal equipment, etc. is not skilled in setting the electronic chart alarm, which may easily lead to accidents such as grounding and collision at sea. Fourth, the fire-proof cotton wrapped on the oil pipe in the engine room is useless. Once the machine leaks oil and splashes, it is likely to spray on the (exposed high temperature) oil pipe, leading to a fire accident. Fifth, firefighters are not skilled in wearing equipment, and the wearing time is three times as long as the specified time. Moreover, the pressure of oxygen cylinders is not checked before wearing masks, and the breathing masks are not sealed when wearing. Once they enter the fire, toxic gases will be inhaled, causing firefighters to suffocate and endanger their lives.

  Six hidden dangers were found during the random inspection of the ship "Zhepu Yuyun 68525" in Zhujiajian Island waters, which mainly included: First, the missing foremast lights, damaged stern lights, and nonstandard anchor lights made it impossible for fishing boats to send out accurate signals during night navigation, which easily led to collision accidents of commercial fishing boats, resulting in group deaths and group injuries. Second, the satellite emergency beacon has expired and is covered by the net. If a fishing boat has a shipwreck, the beacon will not be able to surface to send a distress signal, which will seriously affect the crew’s distress. Third, fire extinguishers and lifebuoys are randomly placed, and the placement is not standardized. In case of danger, the crew cannot save themselves in time, resulting in fire or drowning.

  Suggestions on rectification measures: The unannounced investigation team stressed that the fishing season is closed on May 1st, which is the peak of fishing boats returning to Hong Kong. It is necessary to conscientiously implement the requirements of the Opinions of the the State Council Safety Committee on Strengthening the Prevention and Control of Safety Risks of Water Transportation and Fishing Vessels, strengthen joint law enforcement and warning education among departments, strengthen the management of "regular spot inspection" and prevent fatigue driving and unattended behavior. It is necessary to keep the equipment and facilities such as guidance, fire fighting and lifesaving in good condition at all times, increase the training of personnel in key positions, and improve the safety awareness, responsibility awareness and operational skills of employees. In view of the problems investigated, it is necessary to immediately investigate and reform, that is, change as soon as you know it, strictly implement the main responsibility of the business unit, and ensure that all rectification measures can see practical results. The unannounced investigation team urged Zhoushan Maritime Safety Administration and Ocean and Fisheries Bureau to issue rectification notices of administrative law enforcement orders to the ships involved, and suspended the merchant ships and fishing boats for rectification.